Automated production line conveyor carrying assemblies between process stations
A tender fixes what every bidder must state before anyone compares prices. The datasheet answers part of it.

A tender document does not ask whether your PCB cleaning machine is good. It asks eight questions that have to be answered with numbers, and the specification sheet in your bid pack answers some of them and leaves the rest blank. The fix is a coverage matrix: mark each tender line as quoted, derived from a stated assumption, or answered with a process record.

Two cleaning-equipment notices registered on 12 and 13 November 2026 close on 3 and 4 December, covering 10 machines across three production lines (Source: ebnew.com tender registrations, November 2026). We ran the eight line items such notices hinge on against the three inline platforms in the CHUANGQI catalogue: the CQ-C9610 aqueous inline washer, the CQ-C753 substrate brush cleaner and the CQ-C7320 dry-ice inline system. Three lines appear on all three datasheets. Three appear on some of them. Two appear on none.

Key takeaways

Eight lines a tender fixes before it fixes a price

This audit reads published specification tables for three inline platforms on 20 November 2026 and matches field names against eight line items that recur in public cleaning-equipment notices. It reads field names, not brochure sentences, and it does not read any complete tender text. The counts describe what a datasheet states, not what a machine can do.

A tender has to let every bidder price the same scope, so the technical annex pins eight variables before anyone opens the commercial envelope:

  1. Workpiece envelope — the largest board or pallet that fits, plus the height clearance above it.
  2. Transport rate — conveyor speed or feed rate, in the unit the buyer will run.
  3. Installed power — voltage, phase and connected load.
  4. Footprint and weight — floor area and transport weight.
  5. Compressed air — pressure band and flow.
  6. Noise — sound pressure where the operator stands.
  7. Acceptance evidence — the test method and the record that proves it.
  8. Output per hour — boards per hour at a stated pitch.

This is where bid packs stall. One line in a typical annex asks for cleaning capacity in boards per hour. The datasheet answers the transport question in millimetres per minute, because that is the variable the machine actually sets at the panel. Both statements are true, and neither one is the figure the evaluation committee has to score. The bidder who converts without saying so hands the committee a number nobody can defend; the bidder who states the pitch and shows the arithmetic hands over something checkable.

Where the datasheets answer, and where they go silent

Tender lineDatasheet field that answers itPlatforms publishing it (of 3)
Workpiece envelopeMax workpiece size / PCB size range2
Transport rateConveyor speed or pellet feed rate2
Installed powerPower supply plus connected load3
Footprint and weightMachine dimensions and weight3
Compressed airPressure band and air flow2
NoiseSound pressure level1
Acceptance evidenceNone published0
Output per hourNone published0

Source: CHUANGQI datasheet audit, 20 November 2026 — specification tables for the CQ-C9610, the CQ-C753 and the CQ-C7320. Counts are field-name matches; they are not performance claims and they do not compare machine quality.

The shape of that table matters more than the split. Every platform publishes what a plant engineer needs before delivery date: power, floor space, weight. Fewer publish what a safety or environmental reviewer asks for. Only the dry-ice unit states an ingress rating, and only the aqueous washer states a sound pressure figure. That pattern is not carelessness. It follows what each page is written for — installation planning — rather than what a tender evaluation scores.

The two zeros are structural. Acceptance is not a property of a machine, so it does not belong in a specification row: the CQ-C9610 is inspected batch by batch at the factory, with four documented stages: a 72-hour continuous run, water tightness and spray-pressure calibration, ion cleanliness measured on test boards, and drying temperature uniformity. Hourly output is not a property either. It falls out of conveyor speed and the board pitch you choose, which is why no datasheet can state it honestly without your product data.

Application engineer inspecting a circuit panel during a cleaning check
Acceptance evidence is a record, not a specification row — which is why the annex asks for it separately.

What to write when the datasheet is silent

Three responses keep a bid defensible, and all three are cheaper than a clarification round:

The sample route is the one buyers ask for when the acceptance clause is still open at bid stage. Contaminated panels go to the factory, are cleaned on the machine type that matches the application, and come back documented. The test itself is free of charge, there is no obligation to buy, each request is answered within 24 hours, and the return package is a before/after video, a cleaning report and a process recommendation with the suggested machine type. Courier arrangements are confirmed individually before you send.

None of this replaces the annex. It fills the lines the annex leaves to the bidder, using records you already hold instead of estimates you would have to defend.

Limits of this audit

For the field-by-field comparison a buyer runs between two shortlisted machines, the twelve-field sheet in how to compare PCB cleaning machine specs line by line covers that step; this page stops at what a tender requires from a single bid.

What should a PCB cleaning machine datasheet include for a tender?

At minimum, the six lines a plant needs before delivery: workpiece envelope, transport rate, installed power, footprint and weight, compressed air, and noise. The two lines an evaluation committee scores hardest — acceptance evidence and hourly output — usually sit outside the specification table, so plan to answer them separately.

Can you quote output per hour from a datasheet?

Not directly, and none of the three inline platforms publishes it. Output per hour depends on conveyor speed and the pitch between boards, so the number belongs in the bid response with its assumption stated, not in a specification row.

Is a factory acceptance test enough as tender evidence?

It answers the acceptance line for the machine you are buying, because each production batch is inspected before shipment. If the annex also asks for evidence on the buyer’s own boards, a sample run supplies it. Neither route substitutes for the buyer’s own acceptance criterion.

Does this apply to dry-ice or stencil cleaning equipment?

Partly. The dry-ice platform publishes a feed rate and an ingress rating but no board envelope, so tenders written for aqueous lines do not map onto it cleanly. Stencil cleaning is a separate platform with its own annex wording. Comparing an inline washer against a batch machine first is a different decision, covered in inline versus offline PCBA cleaning machines.

Next step: send the cleaning line items from your tender document, plus one board drawing. We answer each line against the CQ-C9610 inline PCBA water cleaning machine specification, flag the lines that need a process record instead of a number, then come back with a quote within 24 hours. Send us the line items.

About the author

Anne is an Application Engineer at CHUANGQI. She works with EMS and OEM manufacturers on cleaning-process questions: analysing flux and residue findings, sizing the right machine configuration (inline or batch, stencil, nozzle or dry ice), and supporting remote commissioning, acceptance testing and process documentation.

Have a cleaning case you want assessed? Send us the board, flux and volume data →

Discuss Your Cleaning Application →